Index > products > Series
Series
K/J-types thermometer
Model:CHY 800A
Data Storage for 120 samples.
Highly accurate single input thermometer
with 0.1% basic accuracy.
Large display for easy to read.
Robust protective Holster.
Thermocouple offset adjust.
°C/°F selection.
MIN/MAX/HOLD functions.
Display back-light.
Auto-Power Off.
Auto-Range: 0.1/1°.
Wide measuring ranges suit for versatile applications.
Hygro thermometer
Model:CHY 820/ 820U/ 820W/ 820UW(will be discontinued)
U- USB
W- Wireless
Highly stable humidity measurement ±2.5%.
Processing %RH and temperature simultaneously.
Two in one wide range thermometer and humidity function.
Wet/Dry bulb, dew point and %RH.
Easy switching between K/NTC/K-DP.
Max/Min/AVG/REL/HOLD function.
APO function.
Multilogger thermometer
Model:CHY 806/ 806U/ 806W/ 806UW/ 806UWE/ 806WE
U- USB
W- Wireless
USB Port provides excellent user interface. (806xUx Series)
DC 12V adapter.
Wireless two ways transmission. (806xWx Series).
Basic accuracy: 0.05%.
2 Channel Temperature Measuring:
T1, T2 for various thermocouples.
Triply display with set-able backlight:
MAIN for T1, T2.
SECOND for T1, T2.
THIRD for T1-T2, TIME.
DATA LOGGER FUNCTION
Data logger capacity:
Save data: 128 samples with real-time data.
Data logger: 16 sets, Maximum 1024 data capacity.
Easy Reads Data with down and up key on meter.
T/C Offset Adjust.
REC, MAX, MIN, MAX-MIN, AVG, REL, HOLD functions.
T1, T2, T1-T2, Time and Memory No.
Resolution 0.1°C/1°C, 0.1°F/1°F.
Warning beeper with Hi/Lo setting.
TIME, Record interval, APO time setting.
Real time clock with calendar.
Selectable Auto Power Off function.
RTD thermometer
Model:CHY 805/ 805U/ 805W/ 805UW
U- USB
W- Wireless
Single input.
Pt3916/Pt3926/Pt385 RTD standard.
MAX/MIN with elapsed time, AVG, REL, REL RECALL, Hi RECALL, Lo RECALL, HOLD function.
Warning beeper with Hi/Lo setting.
According to temperature standard ITS-90.
°C/°F user-selective.
TIME setting, REL setting.
Resolution 0.1°C or 0.2°F.
Dual input RTD thermometer
Model:CHY 804/ 804U/ 804W/ 804UW
U- USB
W- Wireless
Dual input function.
Pt3916/Pt3926/Pt385 RTD standard.
MAX/MIN with elapsed time, AVG, REL,
HOLD function.
Warning beeper with Hi/Lo setting.
Time setting, REL setting.
According to temperature standard ITS-90.
°C/°F user-selective.
Resolution 0.1°C or 0.2°F.
Previous | Next 1   2   3   4   5   6   7   8